Task #11367 (closed)
Opened 11 years ago
Closed 10 years ago
Bug: ROI coordinates incorrect for .czi data
Reported by: | mlinkert | Owned by: | mlinkert |
---|---|---|---|
Priority: | minor | Milestone: | 5.0.2 |
Component: | Bio-Formats | Version: | 4.4.8 |
Keywords: | ZeissCZIReader | Cc: | sebrhode@… |
Resources: | n.a. | Referenced By: | n.a. |
References: | n.a. | Remaining Time: | n.a. |
Sprint: | n.a. |
Description
Moved from http://fiji.sc/bugzilla/show_bug.cgi?id=649
The Zip file attached to that Bugzilla entry contains the .czi file and screenshots needed to reproduce the problem. As far as I can tell, the ROI coordinates stored in the .czi file are in pixels (not microns).
Change History (3)
comment:1 Changed 10 years ago by mlinkert
comment:2 Changed 10 years ago by mlinkert
- Milestone changed from Unscheduled to 5.0.2
comment:3 Changed 10 years ago by mlinkert
- Resolution set to fixed
- Status changed from new to closed
Fixed with https://github.com/openmicroscopy/bioformats/pull/1078; email forthcoming on ome-users/ome-devel with details of how to try this out prior to 5.0.2.
Branch for post-holiday review: https://github.com/melissalinkert/bioformats/tree/czi-roi-coordinates